תיאור
Stepper Motor Motion Controller CNC Industrial Servo Preset Control Module Panel System
Item Type: Stepper Motor Motion Controller
Case Size(LxWxH): Approx. 99.7 x 72 x 17mm / 3.93 x 2.83 x 0.67in
Screen Structure: 5 digit, high light digital tube
Operating Environment: -5-60 (no condensation)
Output: Output 2. Output Voltage: 0V
Operating Voltage: DC DC12-24V >1A power supply
Opening Size(LxW): Approx. 92 x 69.8mm / 3.62 x 2.75in
Motor Pulse Voltage: Collector 24V, can be directly connected to 5-24V driver
Motor Pulse Frequency: 85K HZ
Input: Enter 7. The input takes 0V as the valid signal
[F] Function Summary: In the actual work, the parameters (internal parameters of the system) that do not need to be modified often are focused on this.
Serial NumberFunction(with * is not recommended to adjust)RangeDefault value
F1Molecular (electronic gear ratio) (see below for details on the specific algorithm)0-655358
F2Denominator (electronic gear ratio) (see below for details on the specific algorithm)0-655355
F3* Minimum speed (the minimum speed limit at which the motor is allowed to operate) Unit: Class0-655350
F4* Maximum speed (the maximum speed limit at which the motor is allowed to operate) Unit: Grade0-17811781
F5Zero finding position (useful only when mechanical zero) Unit: based on gear ratio0-65535.9991.5
F6Zero finding speed (useful only when machine is zero) Unit: level0-6553550
F7Zero seeking mode (0: software zero 1-3: mechanical zero, where 1 is recommended, do not use 2)0-30
F8* Zero function start point (useful only when the machine is zero) Unit: the gear ratio shall prevail0-65535.99965535
F9* Acceleration (the acceleration level of the motor starting to the normal speed, the larger the faster) the acceleration and deceleration values should be consistent as far as possible0-65535 level2000
F10* Deceleration (deceleration level from normal motor speed to stop, the larger the faster) acceleration and deceleration values should be consistent as far as possible0-65535 level2000
F11* System internal debugging parameters, do not set0-2553
F12* System internal debugging parameters, do not set0-42949672956400
Function 13*X0-X1-X2 Input signal filtering time unit: level0-6553540
When there is external interference, set again. The larger the value, the slower the response
F14The magnitude of THE SPEED CHANGE in operation (can be turned off in F16) Unit: Level0-2552
When the motor is in operation, the current running speed can be modified through the knob (encoder) on the panel. The magnitude of the knob change speed is determined by this parameter. The greater the value, the rotary knob, the greater the range of speed! The smaller the better.
Note: The speed after speed change is not saved by default after power failure. If you want to save after power failure, press the "Confirm" button to save in standby state. "Speed-saue" is displayed.
F15Is it automatically returned to zero after startup? (0: does not return to zero upon startup 1: automatically returns to zero upon startup)0-10
Note: If automatic return to zero is set on startup, software zero is used for return to zero by default. The mode needs to be set in [F5-F8] function. If mechanical zero is set, it is recommended to set the zero back to mechanical zero F7=1 for the best effect! Returning to zero can only be a reversal!
F16* Special function Settings0-2550
Value 0- Normal does not enable any special functions (default)
Value 1- Forces knob speed change to turn off.
Value 2- Modifies the motor rotation direction.
Value 4- Enables RS485 communication (following RTU protocol). The agreement specification can be downloaded from the official website.
Value 8- Automatically runs the job when turned on. The controller can be externally connected to the start button, direct wire to start port and 0V short circuit, can also play a similar effect.
Value 16- Running knob speed regulation, whether the forward and reverse change simultaneously. You are not advised to use this function. Note: IF you want to change the speed at the same time, the forward and reverse running speed values should be the same. The P2 = P4. if
If not, the speed will be unexpected.
For example:
1: If you want to modify the motor rotation direction, refer to the above value of 2. So F16 is equal to 2, which means change direction
2: Now to open the RS485 communication function (value :4), and to change the motor rotation direction (value :2). F16=4+2=6
F17* Selective switch P interface or F interface 1- off [P] on [F] 2- on [P] off [F] 3- All off (temporary open: press the [Setting] key before starting up)0-30
F18
-
מזהה Fruugo:
346202909-757272804
-
EAN:
686237112916
מידע על בטיחות המוצר
אנא עיין במידע בטיחות המוצר הספציפי למוצר זה המתואר להלן
המידע הבא מסופק על ידי קמעונאי צד שלישי עצמאי המוכר מוצר זה.
תוויות בטיחות למוצר
אזהרות בטיחות:
-
Not suitable for children under 36 months
-
Choking Hazard
-
Adult supervision recommended
משלוחים והחזרות
שילוח תוך 2 ימים
משלוח מ- סין.
אנו עושים כמיטב יכולתנו להבטיח שהמוצרים שאתם מזמינים יישלחו אליכם במלואם ובהתאם למפרט שלכם. עם זאת, אם תקבלו הזמנה חלקית, או פריטים שונים מאלו שהזמנתם, או שיש סיבה אחרת לכך שאינכם מרוצים מההזמנה, באפשרותכם להחזיר את ההזמנה, או כל אחד מהמוצרים הכלולים בהזמנה, ולקבל החזר מלא עבור הפריטים. הצג מדיניות ההחזרים המלאה