Gm328a Transistor Tester Diode Capacitance Inductance Esr Volt Frequency Meter

‏38.95 ₪
+ ‏32.49 ₪ משלוח

Gm328a Transistor Tester Diode Capacitance Inductance Esr Volt Frequency Meter

  • מותג: Unbranded

Gm328a Transistor Tester Diode Capacitance Inductance Esr Volt Frequency Meter

  • מותג: Unbranded
מחיר מומלץ לצרכן: ‏94.00 ₪
מחיר: ‏38.95 ₪
החיסכון שלכם: ‏55.05 ₪ (58%)
נמכר על ידי:
‏38.95 ₪
+ ‏32.49 ₪ משלוח

במלאי

אנו מקבלים את אמצעי התשלום הבאים

תיאור

Product features: Digital LCD display,easy to read,can display measurement data and graphics Rotary switch control,easy to use for key measurement Press and hold the test button to exit the frequency measurement function. The frequency measurement range is from 1Hz to above 1MHz. When the measured frequency is lower than 25KHz,the cycle is displayed Square wave generator,with multi gear square wave frequency selectable. Rotate the left or right test button to switch to different square wave frequencies,and long press the test button to exit the square wave generator Pulse signal generator,turn left or right test button to adjust the pulse duty cycle from 1% to 99%. Press and hold the test button to exit the pulse signal generator Use 5V Type-c power supply interface for power supply,and customers can also weld 9V battery interface for power supply Automatic shutdown,shutdown current is only about 20nA Note: Before testing the capacitor,first discharge the capacitor,and then insert it into the test base for measurement,otherwise the microcontroller of the tester may be damaged. Input voltage: DC5V Working voltage: about 30mA, Control of transistor tester The tester is controlled by a rotary encoder switch, The rotary encoder switch can be operated in 6 ways: short press,long press,left rotation,right rotation,press and hold left rotation,press and hold right rotation. Press once in the shutdown state to turn on the power and start the test. If no device is detected after one test. Press and hold the switch or rotate the switch left and right to enter the function menu. After entering the function menu,the left or right switch can be selected above or below the menu item. To enter a function item,press the switch briefly. When you need to exit from a function,press and hold the switch. Calibration: The tester calibration is used to eliminate the error of its own components and make the final test results more accurate. Calibration is divided into quick calibration and full function calibration. Operation method for quick calibration: short circuit the three test points TP1,TP2 and TP3 with wires,then press the test button,and observe the screen at the same time. The screen color will become white on a black background,and the prompt message Selftest mode..? will appear After that,press the test button to enter the fast calibration process; If the prompt Self test mode..? appears After that,if no key is pressed within 2 seconds,a normal test process will be conducted,and the resistance values of the wires shorting TP1,TP2,and TP3 test points will be displayed finally. After entering the quick calibration process,some data will appear on the screen,regardless. Wait until a flashing string appears on the screen isolate Probes After that,remove the wires shorting TP1,TP2 and TP3. The quick calibration is completed until the string Test End appears on the screen. For the first calibration,use the full function calibration mode. Full function calibration needs to be entered from the function menu,and another 220nf capacitor needs to be prepared. Full function calibration performs a more comprehensive calibration process and takes longer. After entering the function menu,turn the test button to the menu item Selftest,and then press the test button to enter the full function calibration process. The flashing string short Probes first appears on the screen,At this time,just like rapid calibration,use wires to short circuit the three test points and wait for the calibration process. The flashing string isolate probes appears on the screen When the string 1 - | | - 3>100nf appears on the screen,the prepared 220nf capacitor is installed on test points TP1 and TP3. Wait until the screen prompts Test End,and the full function calibration process is completed. Package list: GM328A transistor tester X1
  • מזהה Fruugo: 428330844-900072736

מידע על בטיחות המוצר

אנא עיין במידע בטיחות המוצר הספציפי למוצר זה המתואר להלן

המידע הבא מסופק על ידי קמעונאי צד שלישי עצמאי המוכר מוצר זה.

אזהרות בטיחות: Under adult supervision, use 4621

משלוחים והחזרות

שילוח תוך 24 שעות

  • STANDARD: ‏32.49 ₪ - משלוח בין יום ו׳ 07 נובמבר 2025–יום ה׳ 13 נובמבר 2025

משלוח מ- סין.

אנו עושים כמיטב יכולתנו להבטיח שהמוצרים שאתם מזמינים יישלחו אליכם במלואם ובהתאם למפרט שלכם. עם זאת, אם תקבלו הזמנה חלקית, או פריטים שונים מאלו שהזמנתם, או שיש סיבה אחרת לכך שאינכם מרוצים מההזמנה, באפשרותכם להחזיר את ההזמנה, או כל אחד מהמוצרים הכלולים בהזמנה, ולקבל החזר מלא עבור הפריטים. הצג מדיניות ההחזרים המלאה

פרטי תאימות המוצר

אנא עיין במידע התאימות הספציפי למוצר זה המתואר להלן.

המידע הבא מסופק על ידי קמעונאי צד שלישי עצמאי המוכר מוצר זה.

יצרן:
המידע הבא כולל את פרטי יצירת הקשר של היצרן של המוצר הרלוונטי הנמכר באתר Fruugo.

  • Anqing Shure Shangmao Youxian Gongsi
  • Anqing Shure Shangmao Youxian Gongsi
  • Room 301, Building 4, Nanshanyuan Community, Yixiu District
  • Anqing
  • China
  • 518000
  • ndqryxjiv@outlook.com
  • 13352983793
  • https://www.fruugo.co.uk/search/?merchantId=21732

האדם האחראי באיחוד האירופי:
המידע הבא כולל את פרטי יצירת הקשר של האדם האחראי באיחוד האירופי. האדם האחראי הוא המפעיל הכלכלי הממונה המבוסס באיחוד האירופי, אשר אחראי לחובות הציות הקשורות למוצר הרלוונטי הנמכר לאיחוד האירופי.

  • SUCCESS COURIER SL
  • SUCCESS COURIER SL
  • CALLE RIO TORMES NUM.1, PLANTA 1,DERECHA, OFICINA3.Fuenlabrada.Madrid.28947 Spain
  • Fuenlabrada
  • Spain
  • 28947
  • successservice2@hotmail.com
  • 34 910602659
  • https://www.fruugo.co.uk/search/?merchantId=21732